LC to APC Patch Cord

Table of Contents

Product Description

The LC to APC patch cord is a fiber optic patch cord used to connect the fiber optic connection between the LC connector and the APC (Angled Physical Contact) connector. In the LC to APC jumper, LC represents the type of connector, and APC represents the end face treatment technology of the connector.

The LC connector is a miniaturized connector commonly used in high-density fiber optic connection environments. The APC connector is a connector that uses beveled end-face treatment technology to reflect optical signals at a smaller angle.

Bevel Physical Contact (APC) processing technology causes optical signals to be reflected at a smaller angle by beveling the end face of the connector, thereby reducing reflection loss and return loss. This processing technology is particularly suitable for single-mode fiber systems and can provide excellent optical performance and connection quality.

It is mainly used to connect LC interface equipment (such as fiber optic switches, fiber optic routers) and APC interface equipment (such as fiber optic transceivers, fiber optic splitters). It can achieve high-speed, stable single-mode optical signal transmission and reduce reflection and interference to ensure the quality and reliability of signal transmission.

Product Application

It can be used in scenarios such as fiber optic access networks, fiber optic backbone networks, and fiber optic distributed systems. It is used to connect fiber optic switches, fiber optic routers, fiber optic terminal equipment, etc., to achieve high-speed and stable single-mode optical signal transmission. Especially where reflection loss and return loss need to be reduced, LC to APC Patch Cord can provide better connection performance.

In high-density data center environments, it is widely used to connect servers, network equipment, storage devices, etc. Its miniaturized LC connector and beveled physical contact APC connector make it suitable for high-density optical fiber connections and can provide high-quality single-mode optical signal transmission to meet the data center’s demand for high-speed and reliable connections.

It is also used in the field of fiber optic sensing. Optical fiber sensing technology uses the characteristics of optical fibers to measure and monitor physical quantities such as temperature, pressure, and deformation. LC to APC Patch Cord can be used to connect fiber optic sensors and data acquisition equipment to achieve high-precision, long-distance fiber optic sensing systems. The bevel processing technology of APC connector reduces reflection loss and provides more stable signal transmission.

Play an important role in the field of fiber optic measurement and testing. It can be used to connect optical power meters, spectrum analyzers, optical time domain reflectometers and other test equipment to perform fiber network performance evaluation, troubleshooting and quality verification. The bevel physical contact processing technology of APC connector reduces reflection loss and improves the accuracy and reliability of measurement and testing.

It is also widely used in cable television (CATV) and fiber optic broadcast systems. It can be used to connect fiber optic modems, fiber optic amplifiers, fiber optic splitters and other equipment to achieve high-quality video and audio signal transmission. The APC connector with beveled physical contact reduces reflection loss and provides clearer and more stable signal transmission.

Product Features

LC to APC patch cords use LC connectors and beveled physical contact (APC) connectors. The LC connector is a miniaturized connector suitable for high-density fiber optic connection environments. APC connector reduces reflection loss and return loss through the beveled connector end face treatment technology, providing better connection performance.

LC to APC patch cord is suitable for single-mode optical fiber systems and can support the transmission of single-mode optical signals. Single-mode fiber has a smaller core diameter and is capable of transmitting high-speed, long-distance optical signals, making it widely used in applications requiring high-speed and long-distance transmission.

LC to APC Patch Cord is able to provide excellent optical performance through the bevel physical contact processing technology of the APC connector. The beveled physical contact reduces the reflection loss between the connector end faces and improves the quality and stability of signal transmission.

The LC to APC patch cord’s beveled physical contact (APC) connector can significantly reduce signal reflection loss. The reduction of reflection loss helps improve the transmission quality of optical signals and reduce signal interference and attenuation.

LC to APC jumper cables undergo strict quality control and testing and are highly reliable and stable. The contacts between its connectors and optical fibers are precisely processed and processed to ensure the reliability and stability of signal transmission.

LC to APC patch cords are compatible with LC and APC connectors and can be used with other compatible fiber optic equipment and connectors. This compatibility makes the LC to APC Patch Cord more flexible and versatile for a variety of fiber optic connection needs.